Clinical Utility of Impulse Oscillometry Parameters in Predicting Asthma Exacerbations
Article information
Abstract
Background
Impulse oscillometry (IOS) provides an effort-independent assessment of respiratory mechanics and is particularly sensitive to small airway dysfunction. Although IOS has been shown to complement spirometry in asthma, its association with exacerbation risk and its relationship with type 2 inflammatory biomarkers remain incompletely understood.
Methods
In this retrospective cross-sectional study, 128 adult patients with physician-diagnosed asthma who underwent both spirometry and IOS at a tertiary hospital between January 2023 and July 2024 were analyzed. Exacerbation events during 1-year follow-up were identified from medical records. IOS parameters included resistance at 5 and 20 Hz (R5 and R20), reactance at 5 Hz (X5), resonant frequency (Fres), area under the reactance curve (AX), and frequency dependence of resistance between R5 and R20 (R5–R20). Correlations between spirometric indices and IOS parameters were assessed. Diagnostic performance for exacerbation events was evaluated using receiver operating characteristic (ROC) analysis. Exploratory analyses examined associations between IOS indices, fractional exhaled nitric oxide (FeNO), and blood eosinophil counts.
Results
Thirty-three patients (25.8%) experienced exacerbations. AX showed the strongest correlations with forced expiratory volume in 1 second (FEV₁)% predicted (r=−0.51, p<0.001) and FEF25–75% predicted (r=−0.42, p<0.001). Patients with exacerbations exhibited significantly higher R5, Fres, AX, and R5–R20 compared with those without exacerbations, with AX demonstrating the largest effect size (Cohen’s d=0.91). In ROC analysis, AX showed the highest discriminative ability for exacerbation events (area under the curve=0.673). FeNO and blood eosinophil counts were not significantly correlated with IOS parameters and showed limited predictive performance when used alone; however, inclusion of AX significantly improved model discrimination.
Conclusion
IOS parameters, particularly AX, are significantly associated with asthma exacerbations and capture mechanical aspects of small airway dysfunction that are not fully reflected by spirometry or type 2 inflammatory biomarkers. IOS may provide clinically meaningful complementary information for risk stratification in asthma.
Introduction
Impulse oscillometry (IOS) is a non-invasive technique used to assess respiratory mechanics by measuring airway resistance and reactance during tidal breathing [1-3]. Unlike spirometry, which requires forced expiratory maneuvers and active patient cooperation, IOS provides information about both central and peripheral airway function by applying pressure oscillations at different frequencies. Low-frequency signals (5 Hz) penetrate the peripheral airways, while high-frequency signals (20 Hz) primarily reflect central airway function [4-6]. In recent years, IOS has emerged as a valuable tool for assessing respiratory function in asthma patients, especially for identifying small airway dysfunction and monitoring disease control [7-9]. The technique provides several key parameters: total respiratory system resistance at 5 Hz (R5), resistance at 20 Hz (R20), reactance at 5 Hz (X5), resonant frequency (Fres), area under the reactance curve (AX), and frequency dependence of resistance between R5 and R20 (R5–R20). These parameters have demonstrated significant associations with spirometric indices and may be more sensitive in detecting airway obstruction compared to traditional spirometry [10-12]. In this context, IOS offers a distinct advantage over spirometry by providing an effort-independent assessment and enhanced sensitivity to peripheral airway abnormalities. This allows IOS to capture clinically relevant airway dysfunction that may not be reflected by conventional spirometric measures alone [3,6]. Asthma exacerbations are a crucial aspect of disease management, often linked to increased airway inflammation and obstruction. Studies have shown that IOS parameters can identify uncontrolled asthma more effectively than conventional spirometry, especially in patients with normal spirometric values [13-15]. The %-predicted R5–R20 has emerged as a particularly useful parameter, with studies demonstrating its superior diagnostic ability in detecting uncontrolled asthma compared to forced expiratory volume in 1 second (FEV₁) [16].
However, standardized cutoff values for IOS parameters have not yet been established, and further research is needed to assess their clinical applicability. To address this gap, this study examined the relationship between IOS parameters and exacerbation events in asthma patients, emphasizing their potential for risk stratification and management. Additionally, it evaluated the diagnostic performance of individual IOS indices in predicting exacerbations.
Materials and Methods
1. Study design and population
This retrospective cross-sectional study involved 128 asthma patients who underwent both spirometry and IOS testing as part of their initial diagnostic evaluation at a single-center tertiary care hospital between January 2023 and July 2024. We collected patient demographics, clinical characteristics, and exacerbation events from medical records. The inclusion criteria were: (1) physician-diagnosed asthma; (2) age ≥18 years; (3) availability of both IOS and spirometry data from the same visit; and (4) complete clinical records. The exclusion criteria included: (1) significant respiratory diseases, such as destructive tuberculous lesions; (2) acute respiratory infections within the previous 4 weeks; and (3) inability to perform acceptable lung function tests. Exacerbation was defined as any documented episode requiring increased treatment (systemic corticosteroids or increased inhaled medication), an emergency department visit, or hospitalization during the 1-year follow-up after testing, in accordance with Global Initiative for Asthma guidelines [17].
The study protocol was approved by the Gachon University Gil Medical Center Institutional Review Board (GUGMCIRB, IRB No. GBIRB2025-277). Informed consent was waived because of the study’s retrospective nature.
2. Impulse oscillometry measurements
IOS measurements were obtained using a commercial device (MasterScreen IOS, Viasys GmbH, Hoechberg, Germany) following international recommendations [18]. Tests were conducted during tidal breathing with patients seated, wearing a nose clip, and supporting their cheeks to minimize upper airway shunting. Recorded parameters included R5, R20, X5, Fres, AX, and R5–R20. For each patient, three to five acceptable measurements were obtained, and mean values were used for analysis. Quality control criteria required a coherence function greater than 0.6 and the absence of artifacts.
3. Spirometry
Standard spirometry was conducted following the guidelines established by the American Thoracic Society and the European Respiratory Society, utilizing the Vmax Encore 22 system (CareFusion, Hoechberg, Germany) [19]. The parameters measured included forced vital capacity (FVC), FEV₁, the FEV₁/FVC ratio, and the forced expiratory flow between 25% and 75% of FVC (FEF25-75%).
Results were expressed as percentages of the predicted values obtained from reference equations for the Korean population [20]. At least three acceptable maneuvers were obtained for each patient, and the optimal values were used for analysis.
4. Statistical analysis
Descriptive statistics were calculated for all variables, presenting continuous variables as mean±standard deviation and categorical variables as frequencies (percentages). The normality of data distribution was assessed using the Shapiro–Wilk test. Correlation analyses between spirometric and IOS parameters utilized Pearson correlation coefficients for normally distributed data and Spearman rank correlation coefficients for non-normally distributed data.
Exploratory correlation analyses between inflammatory biomarkers (fractional exhaled nitric oxide [FeNO] and peripheral blood eosinophil counts) and IOS parameters were performed using Spearman rank correlation due to the non-normal distribution of the biomarker variables. Group comparisons were conducted using the independent t-test or Mann–Whitney U test for two-group comparisons, and one-way analysis of variance (ANOVA) or Kruskal–Wallis test for multiple-group comparisons, followed by post hoc analysis with Bonferroni correction as appropriate.
Exacerbation severity was analyzed as an ordinal outcome (0=none, 1=moderate, and 2=severe) using ordinal logistic regression to evaluate trends across severity categories. Receiver operating characteristic (ROC) analysis was employed to assess the diagnostic performance of individual IOS parameters in detecting exacerbation events. The area under the curve (AUC), sensitivity, specificity, positive predictive value, and negative predictive value were calculated with 95% confidence intervals. Effect sizes for group comparisons were determined using Cohen’s d.
Multivariable binary logistic regression analyses were conducted to develop predictive models for any exacerbation event, using IOS parameters and inflammatory biomarkers as predictors. Odds ratios (ORs) were reported for each one standard deviation increase in continuous variables. Model performance was evaluated through ROC analysis, with internal validation conducted using 5-fold cross-validation.
Statistical significance was set at p<0.05. All analyses were performed using R statistical software version 4.3.0 (R Foundation for Statistical Computing, Vienna, Austria).
Results
1. Patient characteristics and baseline measurements
The study included 128 asthma patients with a mean age of 58.5±17.0 years, ranging from 20 to 86 years. Seventy-five patients (58.6%) were female. During the 1-year follow-up after testing, 33 patients (25.8%) experienced exacerbations, while 95 patients (74.2%) did not. Baseline spirometric parameters showed the following mean values: FVC 88.0%±14.1% predicted, FEV₁ 88.3%±18.5% predicted, FEV₁/FVC 97.4%±14.7% predicted, and FEF25-75% 84.0%±36.1% predicted. Inflammatory biomarker assessment revealed a median FeNO level of 36 ppb (interquartile range [IQR], 26 to 58) and a median peripheral blood eosinophil count of 180/μL (IQR, 90 to 399). The IOS parameters demonstrated the following baseline values: R5 0.444±0.230 kPa·s/L, R20 0.334±0.114 kPa·s/L, X5 –0.121±0.151 kPa·s/L, Fres 15.801±7.242 Hz, AX 1.218±1.804 kPa/L, and R5–R20 0.114±0.144 kPa·s/L (Table 1).
2. Correlations between spirometric (FEV, FEF25–75%) and IOS parameters
Strong and significant associations were found between spirometric indices and IOS parameters (Table 2). Airflow limitation, as indicated by spirometric measurements, was consistently linked with abnormal IOS findings that suggest peripheral airway dysfunction. Notably, the indices representing reactance and frequency dependence of resistance showed the strongest correlations with spirometric variables, indicating that IOS is sensitive to pathophysiological changes in the distal airways. Among the IOS parameters, AX displayed the most consistent and pronounced correlations with both FEV₁% predicted and FEF25–75% predicted, highlighting its potential as a sensitive surrogate marker for small airway impairment. The inverse relationships observed between AX, Fres, and R5–R20 with spirometric parameters suggest that increased airway resistance and decreased compliance are closely associated with declines in conventional lung function indices. In contrast, X5 showed positive correlations, reflecting its role as a measure of reactance. Overall, these findings emphasize the complementary role of IOS in detecting early or subtle airway abnormalities that may not be fully captured by standard spirometry.
3. Impulse oscillometry parameters according to exacerbation status
Patients who experienced exacerbation events displayed significantly altered IOS profiles compared to those without exacerbations (Table 3). Indices reflecting total and peripheral airway resistance, as well as reactance, were consistently more abnormal in the exacerbation group. Notably, R5 and the R5–R20 were both elevated, indicating increased total and small airway resistance. Measures related to reactance also showed significant differences: the Fres and the AX were markedly higher in patients with exacerbations, signifying greater elastic load and reduced compliance in the peripheral airways. Among all IOS parameters, AX exhibited the largest effect size, suggesting it may be the most sensitive indicator of exacerbation-prone airway physiology. In contrast, X5 was more negative in the exacerbation group, indicating impaired lung compliance, although this difference was not statistically significant. R20, which represents central airway resistance, was similar between groups, suggesting that abnormalities in the peripheral airways, rather than the central airways, primarily contributed to the observed IOS changes. Overall, these findings indicate that asthma patients vulnerable to exacerbations exhibit significant dysfunction in the distal airways, as captured by IOS measurements.
4. Diagnostic performance of individual IOS indices for exacerbation events
ROC analysis was conducted to evaluate the diagnostic performance of individual IOS parameters in distinguishing asthma patients with and without exacerbation events. Among these parameters, AX demonstrated the highest discriminative ability, followed by R5–R20 and Fres, suggesting that indices reflecting peripheral airway dysfunction are more closely associated with the risk of exacerbation. R5 exhibited moderate diagnostic performance, while R20 and X5 showed limited ability to differentiate between the two groups (Table 4 and Figure 1).
Diagnostic performance of individual impulse oscillometry parameters for predicting exacerbation events
Receiver operating characteristic (ROC) curves of impulse oscillometry (IOS) parameters for predicting exacerbation events. ROC curves illustrating the ability of IOS indices to distinguish asthma patients with and without exacerbation events. Among the IOS parameters, area under the reactance curve (AX), frequency dependence of resistance between R5 and R20 (R5–R20), resonant frequency (Fres), resistance at 5 Hz (R5), resistance at 20 Hz (R20), and reactance at 5 Hz (X5) are shown. The dashed diagonal line indicates the reference for random discrimination (area under the curve [AUC]=0.5).
5. Exploratory analysis of FeNO, blood eosinophils, and IOS parameters in relation to asthma exacerbation
FeNO (ppb) and peripheral blood eosinophil counts (/μL) were not significantly correlated with IOS indices (R5, R20, R5–R20, X5, Fres, AX; all p>0.20) (Supplementary Table S1). When exacerbation severity was analyzed as an ordinal outcome (0=none, 1=moderate, 2=severe), FeNO and eosinophil counts showed nonsignificant positive trends with higher exacerbation grades. In a logistic model for any exacerbation, biomarkers alone demonstrated limited discrimination (AUC=0.582). However, the inclusion of AX improved model performance (AUC=0.703), and AX remained independently associated with exacerbation risk (OR, 2.11 per standard deviation increase; p=0.0035) (Supplementary Table S2).
Discussion
This study reveals significant associations between IOS parameters and exacerbation events in asthma patients, highlighting their clinical relevance in modern asthma management. Patients experiencing exacerbations displayed distinct IOS profiles, marked by increased airway resistance, elevated Fres, and greater frequency dependence of resistance. These changes reflect pathophysiological alterations in the small airways that often precede noticeable clinical deterioration. The findings support the idea that IOS can serve as a sensitive indicator of small airway involvement, providing insights that traditional spirometry may overlook.
From a pathophysiological standpoint, small airway dysfunction is characterized by airflow heterogeneity, dynamic airway closure, and impaired elastic recoil, which can persist even in clinically stable asthma. Abnormalities derived from IOS, especially increased R5–R20 and more negative X5 or elevated AX, may represent ongoing peripheral airway impairment that spirometry does not adequately capture. Such residual small airway issues can exacerbate airway instability and ventilation inhomogeneity during inflammatory events, thus lowering the threshold for acute exacerbations. In this context, the observed links between IOS metrics and exacerbation events are clinically plausible and reflect significant airway pathology rather than mere statistical correlations.
Among the parameters analyzed, AX emerged as the most robust marker, exhibiting the strongest correlations with spirometric indices (r=–0.51 with FEV₁, r=–0.42 with FEF25–75%) and the largest effect size (d=0.91). In this study, most patients showed preserved FEV₁/ FVC ratios, indicating relatively normal spirometric profiles. In this context, AX may offer superior discriminatory ability compared to R5–R20, as it not only reflects the frequency dependence of resistance but also integrates information on lung compliance, airway closure, and the heterogeneity of peripheral airway function. This likely explains why AX demonstrated a higher AUC than R5–R20 in our cohort, suggesting that AX is particularly sensitive to subtle impairments in small airway function that conventional spirometry may miss.
Consistent with the findings of Kim et al. [21], who reported a significant association between AX and asthma in patients with preserved lung function, our results further emphasize the diagnostic value of AX in detecting small airway dysfunction, even when spirometric parameters appear normal. Fres (d=0.74) and R5–R20 (d=0.66) demonstrated moderate-to-large effect sizes, reinforcing their importance as indicators of exacerbation risk. Although detailed smoking history (packyears) was not available for all participants and could not be fully incorporated into multivariable modeling in this study, subclinical smoking-related airway changes may partially influence IOS, particularly AX, which integrates resistance and reactance. Therefore, residual confounding by smoking/chronic obstructive pulmonary disease overlap cannot be excluded. In contrast, R20 showed a negligible effect, while X5 exhibited a moderately large negative effect, underscoring the differential diagnostic value of various IOS indices. Effect size analysis further highlights that these differences are not only statistically significant but also clinically meaningful, extending the interpretation beyond p-values alone.
ROC analysis confirmed the diagnostic potential of IOS. AX demonstrated the highest discriminatory performance for exacerbation events (AUC=0.673), followed closely by R5–R20 (0.658) and Fres (0.644). Although the discriminative ability of these parameters was moderate, they provide valuable complementary information when integrated into a broader clinical evaluation. Importantly, the optimal Fres threshold identified in this study (23.237 Hz) was higher than in previous reports, which may reflect bias introduced by a small number of patients with markedly elevated Fres values. This underscores the need for larger validation studies to establish reliable and clinically applicable cutoffs.
The results of this study are in line with prior studies showing that IOS, especially R5–R20, can identify uncontrolled asthma more effectively than spirometry [22-24]. Liwsrisakun et al. [22] reported that a %-predicted R5–R20 ≥200 was superior to FEV₁ in predicting uncontrolled asthma, with an AUC of 0.939 compared to 0.712. These results, along with the data, emphasize the enhanced sensitivity of IOS in detecting small airway dysfunction, even in patients with preserved FEV₁/FVC ratios where conventional spirometry may seem normal. This is especially important for asthma phenotypes that exhibit disproportionate small airway involvement. In exploratory analyses, FeNO levels and peripheral blood eosinophil counts did not show significant associations with IOS parameters and had limited ability to predict exacerbation risk when analyzed independently. Although there were nonsignificant trends indicating higher values with increased exacerbation severity, the inclusion of AX significantly improved model performance, and AX remained independently linked to exacerbation risk. This disconnect may be attributed to several factors. First, FeNO and blood eosinophils primarily indicate current type 2 inflammatory activity, while IOS assesses mechanical small airway dysfunction that can persist despite varying inflammatory signals. Second, clinical diversity, including mixed asthma phenotypes such as cough-variant asthma, may obscure direct correlations between inflammatory biomarkers and IOS indices. Third, relying on single time-point biomarker measurements may restrict the ability to capture the cumulative or longitudinal inflammatory burden that is relevant to exacerbation risk. Overall, these findings suggest that IOS effectively captures mechanical aspects of small airway dysfunction that complement, but are not fully represented by, conventional type 2 inflammatory biomarkers.
The differences in IOS parameters between patients with and without exacerbations highlight small airway dysfunction as a ‘treatable trait’ in asthma management. The elevated values of R5, Fres, AX, and R5–R20 in the exacerbation group indicate increased peripheral airway obstruction and reduced lung compliance, which align with ongoing airway inflammation and remodeling [25]. This aligns with current precision medicine strategies that emphasize phenotype-directed therapy based on specific biomarkers and functional measurements.
The findings from IOS have practical therapeutic implications. Extra-fine particle formulations of inhaled corticosteroids and bronchodilators have demonstrated increased efficacy in patients with IOS-defined small airway dysfunction. Furthermore, identifying such dysfunction may help guide the use of biologic therapies in patients with type 2-high asthma phenotypes. Pediatric studies also support the value of IOS, with Hu et al. [13] showing that IOS combined with FeNO achieved excellent diagnostic performance (AUC=0.95) for detecting uncontrolled asthma in children. This suggests that multimodal approaches integrating IOS with other biomarkers can enhance phenotyping and risk stratification across age groups.
Looking ahead, the integration of IOS with emerging biomarkers and advanced computational methods shows promise for personalized asthma care. Advances in artificial intelligence and machine learning applied to oscillometry data may enable the development of predictive algorithms that can identify patients at high risk of exacerbations, forecast treatment responses, and guide individualized therapy [9].
This exploratory analysis, while not the primary focus of the study, revealed a slight improvement in predictive performance when combining AX, R5–R20, and Fres compared to single-parameter models. This suggests that multi-parameter approaches could enhance risk prediction. However, these findings need to be validated in larger, prospective datasets.
Several limitations must be acknowledged. The retrospective, single-center design restricts generalizability, and the relatively small sample size, especially in the severe obstruction group, may have limited statistical power. Exacerbation events were identified from medical records, which may underestimate mild episodes managed in the community. Additionally, the cross-sectional design prevents conclusions about causality or the predictive value of baseline IOS for future exacerbations. Future research should prioritize prospective, multi-center validation using standardized definitions for exacerbations, larger sample sizes, and longitudinal follow-up to determine whether IOS parameters can reliably predict future outcomes.
In summary, this study shows that IOS provides clinically relevant insights into respiratory mechanics in asthma and complements spirometry by detecting small airway dysfunction. Parameters like AX, R5–R20, and Fres demonstrated significant differences between patients with and without exacerbation events, exhibiting moderate but consistent diagnostic performance. Effect size analyses further underscore the clinical significance of these findings. While IOS parameters should not be used in isolation, their integration into a comprehensive asthma assessment could enhance risk stratification, inform treatment decisions, and support precision medicine approaches. With further validation and standardization, IOS has the potential to become a vital component of asthma management.
Notes
Conflicts of Interest
No potential conflict of interest relevant to this article was reported.
Funding
No funding to declare.
Supplementary Material
Supplementary material can be found in the journal homepage (http://www.e-trd.org).
Correlation between type 2 inflammatory markers and impulse oscillometry parameters.
Predictive performance of FeNO, eosinophils, and IOS parameters for asthma exacerbation.